The on-screen ball placement aid is only displayed when the device is looking for a ball (the "ball-lock" indicator light will be flashing red). The ball must be placed within the right or left hitting zone (indicated by the trapezoids) for ball lock to occur.
-
Once the GC2 is locked onto a ball, the "ball-lock" light will turn solid green, indicating the ball may now be struck.
-
Light patterns and corresponding meaning:
SLOW (RED) FLASHING: indicates device is looking for ball
FAST (RED) FLASHING: Indicated ball just outside of ball find area, must be moved towards the center of the box
SOLID GREEN: indicates the ball is recognized and the device is ready to be used.
ALTERNATING (RED/GREEN) FLASHING: indicates ball is detected but device cannot establish a lock -
NOTE: When locked on a ball and connected to a Windows computer running FR1 or FSX software via a USB cable, the Foresight Sports logo will appear on the LCD screen.
When locked on a ball and NOT connected to a Windows computer, the previous shot data will appear on the LCD screen.